Most DK-Lok male connectors can be bored-through thermocouple fittings except those fittings with small male thread like 1/8 in.To order, insert T in DMC male connector part number. Example: DMCT8-8N-S DK-Lok bored-through fittings have no shoulder or sizing angle inside the body. This allows thermocouples or dip tubes to pass beyond the fitting male thread.
Assembly instruction1. Position the length of thermocouple to pass through fitting male thread and hold it to prevent shifting during assembly.2. Wrench tightens the nut 1 1/4 turns from finger tight position, keeping the body steady with backup wrench.• Tighten the nut 3/4 turn for 1/8, and 3/16; 3, and 4mm Tube Fittings.(Bored-Through Male Connector)